8. Connect the Cables
Route the bound transducer cables to the control amplifier location. Drill 1 (52 mm) holes where
needed.
If equipped, route the chromatherapy cable to the planned amplifier location. Follow the same route
as the transducer cables.
Route the inter-connect cable to the control amplifier location. Include a drip loop.
Route the user interface cable to the planned user interface location. Include a drip loop.
NOTE: An auxiliary cable connection can be used to pair a BLUETOOTH
®
device or other
battery-operated audio device so users can play their own music with the vibracoustic bath.
If used, route an auxiliary-in cable (not included) to the control amplifier location.
User Interface
Transducer Wires
Inter-Connect
Cable
Heated Surface
Control
Chromatherapy
Cable (If Equipped)
Optional Auxiliary-In
Cable
Transducer
Control Board
Kohler Co. 13 1237790-2-B